Seegene HOME > Product > Seeplex® > VRE ACE Detection
Drug Resistance Detection
Detection of vanA & vanB genes
which cause vancomycin-resistance
Seeplex® VRE ACE Detection is designed to detect the
vanA and vanB genes which cause vancomycin
-resistance in enterococci isolated from stool
culture in a single test.
(Analyzing product, DNA amplification )
NOT AVAILABLE IN THE US
Enterococci are normally indigenous bacteria found in the GI tract and female genitals, but recently they were recognized as major pathogens causing urinary tract infections and sepsis by nosocomial infection.

Vancomycin, which is used in the treatment of enterococci infection, is a drug that has an antibacterial effect by forming a complex with the D-alanyl-D-alanine terminal of the peptidoglycan precursor to block transglycosylation and transpeptidation during the synthesis of the cell wall of Gram-positive cocci. However, vancomycin-resistant enterococci (VRE) tend to multiply rapidly due to the high frequency and continuous
use of vancomycin.
The Seeplex® VRE ACE Detection is a PCR method that incorporates DPO™ technology with high sensitivity and specificity, and is a product that can test for the vancomycin- resistant vanA gene and the vanB gene of enterococci in one test.

A. Single PCR test identifying vanA, vanB gene cause of Vancomycin-resistant of enterococci.
B. Applicable for Auto-capillary Electrophoresis device
Test result is rapidly and easily obtained by automating band reading and analysis process after PCR.
C. Contamination Prevention System
One-time PCR reduces the carryover contamination risk, and 8-MOP, which is included in each set of products, eliminates the contamination risk from PCR.
 
D. Multiplex PCR with high sensitivity and specificity by applying DPO™ (Dual Priming Oligonucleotide) technology
DPO- based primers contain two priming parts, so that the target gene only is specifically amplified.
E. Accurate system for interpretation of results
Internal Control and Positive Control are included in each set of products.
- Enterococci cultured in Enterococcosel broth /agar - vanA
- vanB
ScreenTape®
System
(Agilent
Technologies)

MCE®-202
MultiNA
SHIMADZU
Product Cat. No. Size
Seeplex® VRE ACE Detection VR1201Y 50 rxns
  • As this product is Medical Device, please read 'caution' and 'instruction' before use.
  • Deliberation number : 2013-I10-01-0833
SEARCH
side 배너 제품부분
Simultaneous detection of 16 viruses using...
Obtained CE-IVD marking for Anyplex™ Flu...
Launched Anyplex™ TV/MH Real-time Detect...
Detection of T. vaginalis and M. hominis