Infectious Pathogen Detection
|
| Detection of diarrhea-causing viruses and bacteria |
Seeplex® Diarrhea ACE Detection
detects diarrhea-causing viruses and/or
bacteria directly from stool.
(Analyzing product, DNA amplification )
|
|
|
   |
|
|
|
 NOT AVAILABLE IN THE US |
Result of conventional method takes 2~3 days and might show false-negative result.
With multiplex PCR system based on DPO™ technology, the Seeplex® Diarrhea ACE Detection can detect 4 viruses and/or 10 bacteria. |
 |
| A. |
Simultaneous detection of diarrhea-causing viruses and/or bacteria directly |
| B. |
Multiplex PCR with high sensitivity and specificity by applying DPO™ (Dual Priming Oligonucleotide) technology |
| |
DPO- based primers contain two priming parts, so that the target gene only is specifically amplified. |
| C. |
Accurate system for interpretation of results |
| |
Internal Control and Positive Control are included in each set of products. |
| D. |
Applicable for Auto-capillary Electrophoresis device |
| |
In addition to Agarose gel electrophoresis, application of Auto-detection system provides easy and convenient results read-out. |
| E. |
Contamination Prevention System |
| |
One-time PCR reduces the carryover contamination risk, and 8-MOP, which is included in each set of products, eliminates the contamination risk from PCR. |
 |
| - Stool |
|
 |
| Virus panel [Panel V] |
Rotavirus
Norovirus GI
Norovirus GII
|
|
Enteric adenovirus
Astrovirus |
| Bacterial panel 1 [Panel B1] |
Salmonella spp. (S. bongori and S. enterica)
Shigella spp.
(S. flexneri, S. boydii, S. sonnei and S. dysenteriae)
Vibrio spp.
(V. cholerae, V.parahamolyticus and V. vulnificus)
Campylobacter spp. (C. jejuni and C. coli) Clostridium difficile Toxin B |
| Bacterial panel 2 [Panel B2] |
Clostridium perfringens
Yersinia enterocolitica
Aeromonas spp.
(A. salmonicida, A. sobria,
A. bivalvium, and A.hydrophila)
E. coli O157:H7
Verocytotoxin-producing E. coli (VTEC) |
|
 |
 |
Caliper
LabChip® Dx
(CALIPER
LIFESCIENCES)

|
 |
MCE®-202
MultiNA
SHIMADZU
 |
 |
ScreenTape®
System
(Agilent
Technologies)
 |
|
|
|
|
|
|
| Product |
Cat. No. |
Size |
| Seeplex® Diarrhea ACE Detection Set |
DR6000Y |
50 rxns |
Seeplex® Diarrhea-V ACE Detection  |
DR6411Y |
50 rxns |
| Seeplex® Diarrhea-B1 ACE Detection |
DR6501Y |
50 rxns |
| Seeplex®Diarrhea-B2 ACE Detection |
DR6502Y |
50 rxns |
|
|
|
|
- As this product is Medical Device, please read 'caution' and 'instruction' before use.
- Deliberation number : 2013-I10-01-0824
|
|
|
|
|
|