Human > Human Papillomavirus Detection > Auto-capillary Electrophoresis (ACE) method
*NOT FOR USE IN DIAGNOSTIC PROCEDURES IN THE U.S.
Seeplex¢ç HPV4 ACE Screening
In Vitro Diagnostics Use
Information | What is HPV and Cervical cancer?
Simultaneously genotyping (HPVs 16 and 18) and screening
|
The Seeplex¢ç HPV4 ACE Screening is designed to
simultaneously genotype (HPVs 16 and 18) and screen for
HPV 11 high-risk and 5 low-risk types from patients¡¯ samples
(cervical swabs).
Cervical cancer, which progresses from the precancerous
stage to invasive cancer, has 7-20 years of precancerous stage;
consequently early diagnosis is possible when HPV infection
is suspected. HPV low-risk group, including HPVs 6 and 11,
may cause genital warts. On the other hand, HPV high-risk
group may lead to the development of cervical cancer;
especially, HPVs 16 and 18 are associated with 70% of cervical
cancer case. Seeplex¢ç HPV4 ACE Screening can indentify HPVs
16 and 18 and also screen for HPV high and low-risks at the
same time. |
|
Introducing a useful reference for diagnosis of HPVs:
Castle P.E. et al. The potential utility of HPV Genotyping in screening and clinical
management. 2008. J Natl Compr Canc Netw 6(1):83-95. (review)

Fig. & Table. Example
 Click the image for large view.
Figure & Table. Amplified PCR products using Seeplex¢ç HPV4 ACE Screening (Rapid
&
easy interpretation using ScreenTape¢ç System)
Features
- Simultaneous genotyping ( HPV 16, 18) and screening for HPV high-risk
and low-risk types
- Multiplex PCR with high sensitivity and specificity by applying DPO¢â
(Dual Priming Oligonucleotide) technology
DPO ¢â (NET* approved) based primers contain two priming parts so that only target gene
is specifically amplified.
*NET (New Excellent Technology) is approved Korea Ministry of Education, Science, and Technology.
- Applicable for Auto-capillary Electrophoresis device
PCR amplicons are separated and analyzed automatically; consequently, rapid and easy
interpretation of the results is made possible.
- Contamination Prevention System
One-time PCR reduces the carryover contamination risk, and 8-MOP, which is included in
each set of products, eliminates the contamination risk from PCR.
- Accurate system for interpretation of results
Internal control and positive control are included in each set of products.
Order information
|
| |
 |
Product
|
 |
Cat. No. |
 |
Size |
|
|
| |
 |
Seeplex¢ç HPV4 ACE Screening (CE mark) |
|
HP1400Y |
 |
50 rxns |
|
* Note: If you need more information for the primer mixture, please contact us.
|
* Storage:
Short term storage : 4¡É
Long term storage : -20¡É
In case of the 2X Multiplex Master Mix, 4 ¡É for short-term storage and -20¡É for long-term
storage are recommended. Avoid repetitive thawing/freezing as it may decrease the activity
of the Master Mix.